Price | RM25.00 - RM35.00 RM50.00 - RM60.00 |
Brand | China OEM |
Availability | In Stock |
Operating Voltage
|
|
Quantity |
|
- Mini and lightweight
- Segment Display
- Alarm Function
Digital Temperature Control Module, Alarm, 12VDC, 24VDC, 240VAC, XD-W2308
The temperature control module has a control range of -55 to 120ºC with an measurement accuracy of 0.2^ Full Scale.
Features:
- Mini and lightweight
- Segment Display
- Alarm Function
Tech Specs:
Attribute | Value |
---|---|
Package | Module |
Operating Voltage Options | 12VDC, 24VDC, 240VAC with a transformer |
Control Type | Temperature Control |
Control Output | Relay, rated @ 10A 250V |
Number of Outputs | 1 |
Measurement & Control Range | -55 - 120ºC |
Control Step | 0.1ºC |
Resolution | 0.1ºC, < 99.9ºC 1ºC, > -99.9ºC |
Accuracy | 0.2% Full Scale |
Display Type | Segment Digital Display |
Input Temperature Probe | NTC10K(B3950), 1 meter length |
Termination Type | Screw |
Dimension | 100 x 48 x 28mm |
Mounting Type, Mounting Dimension | Panel Mount, 71 x 41mm |
Ambient Operating Temperature | -30 - 60ºC |
Ambient Operating Humidity | 25 - 85% |
Module Button Layout:
Instructions:
Parameters | Description | Setting Range | Factory Setting Values |
---|---|---|---|
P0 | Operationg Mode | Cooling (C) / Heating (H) | C |
P1 | Temperature Differential | 0.1 - 30°C | 2°C |
P2 | Non-functional mode | - | 120°C |
P3 | Non-functional mode | - | -55°C |
P4 | Temperature Off / Calibration | -10 - 10°C | 0 |
P5 | Time ON Delay | 0 - 10 minutes | 0 |
P6 | Alarm Function | -55 - 120°C | Off |
P7 | Setting Lock | On / Off | Off |
P8 | Factory Reset | On / Off | Off |
Turning On / OFF the module
- Press ENT Key for at least 5 sec to turn on the module.
- After turning on, the module shows a measured temperature.
- Press ENT Key for at least 5 sec to turn off the module.
Setting Control Temperature
1) Press SET Key once to go to Adjustsment Level for control temperature, the control temperature is shown in flashing mode.
2) Use Up / Down Key to set a value between -55 - 120°C.
3) Press SET Key again to save.
Setting P0, Operation Mode, Cooling (C) / Heating (H)
1) Press SET Key for at least 3 sec to go to Initial Setting Level, the display shows 'P0'
2) Press SET Key again to go to Adjustment Level for P0.
3) Use Up / Down Key to set a mode, C / H.
4) Press SET Key again to save.
Setting P1, Temperature Differential
A temperature differential provides a temperature range corresponding to F1, where the module will stay ideal.
Example, if control temperature and P1 are set to 15°C and 1°C respectively, the module will stay ideal between 15°C and 16°C (control temperature + P1).
Equation: Upper-limit = control temperature + P1, Lower-limit = control temperature.
1) Press SET Key for at least 3 sec to go to Initial Setting Level, the display shows 'P0'
2) Use Up / Down Key to select P1.
3) Press SET Key again to go to Adjustment Level for P1.
4) Use Up / Down Key to set values between 0.3 - 10°C.
5) Press SET Key again to save.
Setting P4, Temperature Offset / Calibration
Temperature offset is a feature that lets you adjust the room temperature reading.
This helps if the temperature control module is in a slightly warm or cold spot, or if the room temperature does not match your old thermostat.
This also helps when the given NTC probe does not match the desired accuracy.
Equation 1: temperature offset = room's actual ambient temperature - temperature measured
Equation 2: temperature calibration = temperature measured using another device - temperature measured
1) Press SET Key for at least 3 sec to go to Initial Setting Level, the display shows 'P0'
2) Use Up / Down Key to select P4.
3) Press SET Key again to go to Adjustment Level for P4.
4) Use Up / Down Key to set values between -10 - 10°C.
5) Press SET Key again to save.
Setting P5, Time ON Delay
ON time delay is generally required for a refrigerator compressor.
1) Press Setting Key for at least 3 sec to go to Initial Setting Level, the display shows 'P0'
2) Use Up / Down Key to select P5.
3) Press SET Key again to go to Adjustment Level for P5.
4) Use Up / Down Key to set values between 0 - 10 minutes.
5) Press SET Key again to save.
Setting P6, Alarm Function
ON time delay is generally required for a refrigerator compressor.
1) Press Setting Key for at least 3 sec to go to Initial Setting Level, the display shows 'P0'
2) Use Up / Down Key to select P6.
3) Press SET Key again to go to Adjustment Level for P5.
4) Use Up / Down Key to turn On / Off the alarm function.
5) Press SET Key again to go to Adjustment Level for Temperature (that trigger the alarm).
6) Use Up / Down Key to set a value between -55 - 120°C.
7) Press SET Key again to save.
Setting P7, Setting Lock
All setting can be locked using this feature.
1) Press Setting Key for at least 3 sec to go to Initial Setting Level, the display shows 'P0'
2) Use Up / Down Key to select P7.
3) Press SET Key again to go to Adjustment Level for P7.
4) Use Up / Down Key to turn On / Off the this feature.
5) Press SET Key again to save.
Setting P8, Factory Reset
All setting can be reset using this feature.
1) Press Setting Key for at least 3 sec to go to Initial Setting Level, the display shows 'P0'
2) Use Up / Down Key to select P8.
3) Press SET Key again to go to Adjustment Level for P8.
4) Use Up / Down Key to turn On / Off the this feature.
5) Press SET Key again to save.
Wiring Diagram:
Assembly Instructions:
Useful Videos:
Unboxing:
Settings:
Enable Alarm Function:
1x temperature control module
1x probe
1x English & Chinese user manual